Evco S.r.l. • EC 6-295 P220 S001 • Sheet 1/3
1 PREPARATIONS
1.1 How to install the instrument
On DIN rail (it is not supplied by the builder).
DIN rail installation (it is not supplied by the builder).
smart guide
EC
6-295P220S001
ON-OFF digital controller for ventilated re-
frigerating units
Version 1.01 of 15
th
March 2005
File ec6295p220s001_eng_v1.01.pdf
PT
EVCO S.r.l.
Via Mezzaterra 6, 32036 Sedico Belluno ITALY
Phone 0039-0437-852468 • Fax 0039-0437-83648
[email protected] • www.evco.it
2 OPERATION
2.1 How to turn the instrument ON/OFF
If you have to turn the instrument ON/OFF:
• press
for 2 s
During the normal operation the instrument shows the cabinet
temperature.
2.2 How to silence the buzzer
If you have to silence the buzzer:
• press
2.3 How to activate the defrost by hand
If you have to activate the defrost by hand:
• press
for 4 s
Unless the evaporator temperature is below the defrost end tem-
perature you have set with the parameter d2, the defrost will
not be activated.
2.4 How to turn the cabinet light ON/OFF
If you have to turn the cabinet light ON/OFF:
• press
2.5 Compressor thermal protection
The activation of this input forces the compressor OFF by hard-
ware and software.
3 REAL TIME CLOCK
3.1 How to set the clock
Press
for 2 s : the instrument
will show
Press or for selecting
If you have to modify the value of the hour:
• press
and or
If you have to modify the value of the minutes:
• release
and press it again during the
modification of the hour,
then ...
• press
or
If you have to quit the procedure:
• press
or as long as the instrument
shows the cabinet tem-
perature or do not oper-
ate for about 30 s.
ENGLISH
Vue de la page 0
1 2 3 4 5 6

Résumé du contenu

Page 1 - 6-295P220S001

Evco S.r.l. • EC 6-295 P220 S001 • Sheet 1/31 PREPARATIONS1.1 How to install the instrumentOn DIN rail (it is not supplied by the builder).DIN rail in

Page 2

6.2 Evaporator temperature showingIf you have to show the evaporator temperature:• gain access the additional functions• pressor for selecting • press

Page 3

Evco S.r.l. • EC 6-295 P220 S001 • Sheet 2/38 ALARMS8.1 AlarmsINDICAT.every 2 sEvaporator fan LEDif it is lighted, the evaporator fan will be ONif it

Page 4

evapora-tor probealarmmulti-functioninputalarmuppertempera-ture alarm• the connection in-strument-cabinetprobe is wrong• the cabinet tempera-ture is o

Page 5

Evco S.r.l. • EC 6-295 P220 S001 • Sheet 3/3relay working in accordance with the instrument mode (the relay will be activated if theinstrument is ON a

Page 6

10 WORKING SETPOINT AND CONFIGURATION PARAMETERS10.1 Working setpointLABEL MIN. MAX. U.M. DEF. WORKING SETPOINTr1 r2 °C/°F (5)0.0 working setpoint10.2